FlowCalcTM Flow Computer

Code: FC

FlowCalcTM Advantage:

  • Flexible design with power and communication options to meet site needs.
  • Custody compliant.
  • Local data logging capabilities.
  • Advanced diagnostic software can continually monitor and verify the meter’s primary flow element health and confirm output uncertainty.
  • Advanced diagnostic software can reduce need to re-calibrate resulting in less time spent on site.
  • User configurable for multiple differential pressure primary flow elements. Such as: orifice, venturi, flow nozzle, wedge, cone.
  • Push button interface.
  • Volumetric or mass flow monitoring of most liquids, gases, and steam.
  • Mass flow equations - real gas, ideal gas, AGA 8, API 2540.
  • When used in conjunction with VorTek Instruments’ VorConeTM, FlowCalc can provide a measurement of fluid density, volumetric flow rate and mass flow rate without any fluid information being required from an external source.
  • When used in conjunction with VorTek Instruments’ VorConeTM, FlowCalc can provide a reliable steam quality (steam dryness) measurement as well as mass flow measurement.
  • When used in conjunction with VorTek Instruments’ VorConeTM, FlowCalc can calculate the density of changing gas mixtures. For example, natural gas is typically a composition of many different gases which can vary over time and vary by application.
  • Energy Monitoring–ability to compute and output energy consumption with select fluids. Steam, water, and heat transfer fluids.
  • Low power.
  • Modbus, BACnet, Power over Ethernet (PoE) communications available.
  • HART protocol communications – Standard.
  • Approvals pending.

 

Verification System

Differential Pressure Verification System – DP Health CheckTM DP Health Check is a comprehensive verification system for Differential Pressure (DP) meters. Utilizing a third pressure port downstream of the DP meter and reading three DPs, DP Health Check analyses not just the traditional single DP reading, but the entire pressure field. The additional information expands the capability of the DP meter, offering a full diagnostic suite. DP Health Check creates a smart DP meter allowing for condition based maintenance operations.

DP Health Check creates seven diagnostic checks, i.e. one DP integrity check, three separate inter-comparible flowrate predictions, and three DP ratios comparible with the baselines. The HMI (human-machine interface) is designed for simplicity: the seven diagnostics are plotted as four points on a graph with a 1x1 box. All points inside the box shows the meter is func-tioning normally see Display for Correctly Operating Meter. Any points outside the box shows a potential metering issue. Display for Varying Quality Saturated Steam Flow & Display for Drifting DP Transmitter show response to varying saturated steam quality and single phase DPt reading error resectively. Pattern recognition technology allows the source of the problem to be directly identified

Ambient Temperature

Ambient Operating: -40 to 140°F (-40 to 60°C)

Ambient Storage: -40 to 185°F (-40 to 85°C)

Power Requirements

DCH option: 12-36 VDC, 300mA, 9W max

DCHPOE: 12-28 VDC or Power over Ethernet, 5 Watts maximum

Display Alphanumeric 2 line x 16 character LCD digital display Six pushbuttons for full field configuration Pushbuttons can be operated with magnetic wand without removal of enclosure covers Display can be mounted in 90° intervals for better viewing
Input Signals
  • 4-20mA (Flow, Pressure, Temperature)
  • Pulse
  • Frequency
  • Frequency
  • RTD (Ohm)
  • Modbus
  • BACnet
Output Signals

nalog: 4-20 mA (Volumetric flow, mass flow, density, pressure, temperature)

Alarm: Solid state relay, 40 VDC

Totalizer Pulse: 50 millisecond pulse, 40 VDC

Volumetric or Loop Powered Mass: One analog, one totalizer pulse, HART

Multivariable option: Up to three analog signals, three alarms, one totalizer pulse, HART

Multivariable option: Modbus or BACnet process monitoring

CPU

Type: 32 bit 250 MHz

Flash: 8 MB

RAM: 64 MB DDR2

Approvals Pending

 

Model Number Information - FlowCalc™ Flow Computer
Parent Number Code FC Flow Computer
Feature 1: Multivariable Options

VEI External Flow Input

VEIET External Flow Input and External RTD Temperature Input

VEIETEM External Flow Input, External RTD Temperature Input, External RTD Temperature Input

Feature 2: Input Power

DCH 12-36 VDC, 300mA, 9W max. – use with 1AH, 1AM, 3AH, 3AM

DCHPOE 12-28 VDC or Power over Ethernet, 5 Watts maximum, required on 1AMIP, 1ABIP, 3AMIP, 3ABIP    *Adds additional input options

AC 100-240 VAC, 50/60 Hz line power, 5W max. – use with 1AH, 1AM, 3AH, 3AM

Feature 3: Output

1AH One analog output (4-20 mA), one alarm, one pulse, HART Communication Protocol, DCH or AC option only *

1AM One analog output (4-20 mA), one alarm, one pulse, MODBUS RTU Communication Protocol, DCH or AC option only *

1AMIP One analog output (4-20 mA), one alarm, one pulse, MODBUS TCP/IP Communication Protocol, DCHPOE ONLY*

1AB One analog output (4-20 mA), one alarm, one pulse, BACnet MS/TP Communication Protocol, DCH or AC option only *

1ABIP One analog output (4-20 mA), one alarm, one pulse, BACnet/IP Communication Protocol, DCHPOE ONLY *

3AH Three analog outputs (4-20 mA), three alarms, one pulse, HART (VT,VTP only), DCH or AC option only *

3AM Three analog outputs (4-20 mA), three alarms, one pulse, MODBUS RTU (VT,VTP only), DCH or AC option only *

3AMIP Three analog outputs (4-20 mA), three alarms, one pulse, MODBUS TCP/IP (VT,VTP only), DCHPOE ONLY*

3AB Three analog outputs (4-20 mA), three alarms, one pulse, BACnet MS/TP (VT,VTP only), DCH or AC option only *

3ABIP Three analog outputs (4-20 mA), three alarms, one pulse, BACnet/IP (VT,VTP only), DCHPOE ONLY * *Includes scaled frequency output

Feature 4: DP Diagnostics DP DP Diagnostics Available *Must select DCHPOE option